Open Access

Table 1

Studies included.

Study Surgical technique Number of patients Mean age (years) Mean follow-up Post-operative assessment scores Evaluation of CC distance Study Design/Level of Evidence Complications
Hou et al. [40] Allogenous semitendinosus graft/single tunnel 11 37 16 months Percentage of good to excellent outcomes: 18% Not reported Retrospective study/III Coracoid fracture: 1 case
Allogenous semitendinosus graft/two tunnel 10 42 Percentage of good to excellent outcomes: 70% Wound infection: 2 cases
Kumar et al. [34] Modified Weaver-Dunn procedure 31 42 40 months Mean OSS pre op: 28 ± 11 Not reported Case series/IV Failure: 3 cases
OSS post op: 42 ± 10 Superficial wound infection: 3 cases
Surgilig technique 24 Mean OSS pre op: 26 ± 9 Implant failure: 1 case
OSS post op: 45 ± 7 Superficial wound infection: 4 cases
Yoon et al. [22] Hook plate 24 38.8 ± 14.2 16 ± 12.8 months VAS: 1.6 ± 1.5 Pre op: 215.7 ± 50.9% Case series/IV No cases of AC joint subluxation
CS: 90.2 ± 9.9 Post op: 106.1 ± 10.2% Acromion erosion: 9 cases
CC ligament reconstruction/synthetic ligament 18 42.2 ± 12.3 17.4 ± 4.3 months VAS: 1.3 ± 1.3 Pre op: 239.9 ± 59.2% AC joint subluxation: 6 cases
CS: 89.2 ± 3.5 Post op: 133.6 ± 36.7%
Li et al. [19] Arthroscopic CC reconstruction/synthetic ligament 32 40.3 29.6 ± 6 months ASES: 96 ± 5.1 Loss of reduction: 1/32 cases Retrospective Comparative study/III Weaver Dunn group: higher rate of loss of reduction
UCLA: 34.2 ± 1.5
Open modified Weaver Dunn 31 ASES: 94.5 Loss of reduction: 7/31 cases
UCLA: 33.7 ± 1.4
Tang et al. [39] Double Endobutton 31 No significant difference in age between the two groups 11–35 months CMS: no significant difference between groups (P > 0.05) Not reported Case series/IV Loss of CC reduction: 1 case
Suture anchor + Endobutton plate 25 Karlsson grading no significant difference between 2 groups (Z = −0.628, P = 0.530) Ectopic ossification: 6 cases(both techniques)
Barth et al. [41] Double endobutton arthroscopic technique in 93% of cases. 116 37 12 months CMS: >85/100 Pre op: 214%(vertical) Non-randomized comparative study/II Early loosening: 3 cases
QuickDASH functional disability <10 in 75% of patients Pre op: 4 mm (horizontal) Surgical infection: 2 cases
Additional acromioclavicular stabilization of the AC joint in 50% of cases. Post op: 128% (vertical) Reflex sympathetic dystrophy: 7 patients
Post op: 0 mm (horizontal) Distal clavicle osteolysis: 1 case
Device impingement:5 cases
Coracoid fracture: 1 case
Cisneros et al. [18] Arthroscopic CC fixation/synthetic ligament 20 36 >24 months Global satisfaction: 8.85 ± 0. 93 Not reported Retrospective Comparative/III Implant failure: 1 case
VAS score: 0.40 ± 0.50 Surgical wound granulomas; 2 cases
Scapular dyskinisis: in 15%
Hook plate 11 41 Global satisfaction: 8.00 ± 1.18, P = 0.035 Surgical site infection: 1 case
VAS score 1.45 ± 1.51, P = 0.007 Inability of metalwork removal: 1 case
Scapular dyskinesis: in 18.18%
Vrgoc et al. [12] Open Reduction + K-wires + Fiber-Tape 10 41.6 At least 12 months No significant statistical difference between techniques Not reported Case series/IV Not specifically reported
Arthroscopic fixation/Tight-Rope 6 37.8
Yin F et al. [36] Autologous plantaris graft +hook plate 15 No difference between age groups 21.4 months CMS: no difference between techniques CC distance: similar results between the two techniques Case series/IV Not specifically reported
Allogenic tendon + hook plate 16 VAS: no difference between techniques
ROM: no difference between techniques
Faggiani et al. [20] Mini open AC repair/MINAR system 8 36.94 13 months CMS: 89.61 Not reported Retrospective cohort study/II Not specifically reported
OMS: 46.13
SST: 11.38
Dog Bone arthroscopic technique 8 CMS: 92.6
OMS: 46.25
SST: 11.75
Metzlaff et al. [24] Mini open AC repair (MINAR)/synthetic ligament 44 36.2 32 months CMS: no difference between techniques Not reported Retrospective Comparative/III Periarticular ossification: 11 cases
Taft:no difference between techniques Periarticular ossification: 8 cases
Hook plate 44 ACJI: no difference between techniques
Kocaoglu et al. [35] CC reconstruction/autogenic palmaris Longus graft/GraftRope system 16 39.7 44.9 months ASES: superior in patients with CC reconstruction Comparison to the uninjured side: mean 1.1 mm Retrospective Cohort study/II Loss of reduction in both groups, higher in the Weaver Dunn group
Modified Weaver Dunn + Tightrope 16 CMS: superior in patients with CC reconstruction Comparison to the uninjured side: mean 3.3 mm
Yin J et al. [37] Hook plate + double tunnel CC reconstruction/conjoint tendon graft 25 46 19.9 months CS: 89.5 Increase in the CC distance after the removal of the hook plate by 25–100% Case-control study/III Pain and swelling at the site of tendon harvest
ASES: 92.6
VAS: 2.5
Hook plate 26 44.5 21–27 months CS: 79.3 Acromion erosion: 46%
ASES: 82.3 Subacromial impingement: 23%
VAS: 4.1
Wang et al [23] CC and AC reconstruction/allogenic tendon 8 49 >48 months CMS: 94.4 Not reported Case series/IV No complications noted
UCLA score: 33.5
Hook plate fixation 8 41.3 CMS: 93.8
UCLA score: 34.1
Stein et al [21] Hook plate 27 37.7 24 months Taft: 9.4 ± 1.7 Equal loss of reduction CC distance in 24 months Cohort study/II No complications noted
CS: 90.2 ± 7.8
Arthroscopic double-button 29 34.2 Taft: 10.9 ± 1.1
CS: 95.3 ± 4.4
Chang et al [38] Hook plate 26 50 11 months VAS: 4.5 ± 2.3 CC distance similar in both groups Therapeutic study/II Subacromial osteolysis: less in the combined technique group.
UCLA: 19.9 ± 4.9
ASES: 51.9 ± 17.8
Hook plate + CC tape augmentation 21 44 9.5 months VAS: 2.3 ± 1.4
UCLA: 27.2 ± 4.0
ASES: 73.8 ± 13.1
Chernchuijit et al [27] Arthroscopic AC fixation/suture button 29 No difference between age groups >18 months SAC: 8 No difference in the CC distance Retrospective Cohort study/II Loss of reduction: >50% of patients in the fixation group
Nottingham: 10
Arthroscopic anatomic AC reconstruction/suture tape 29 SAC: 20
Nottingham: 19

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.