Figure 1

Download original image
Kaplan-Meyer survival analysis of the two groups, taking into account both infection-related and aseptic causes of revisions. Polyethylene exchange as part of the debridement, antibiotics, and implant retention procedure has been included as implant failure in this analysis. Kaplan Meier survival analysis showed that group B (cemented implants) did not have significantly higher risk of all-cause revision (infections and aseptic loosening) compared to group A (cementless implants) (p = 0.57).