Issue |
SICOT-J
Volume 11, 2025
|
|
---|---|---|
Article Number | 2 | |
Number of page(s) | 8 | |
Section | Knee | |
DOI | https://doi.org/10.1051/sicotj/2024059 | |
Published online | 13 January 2025 |
Original Article
Functional alignment is a feasible alignment strategy in robotic assisted total knee arthroplasty for knee osteoarthritis with extra-articular deformity – A case series
Department of Orthopaedic Surgery, Joint Replacement Unit, Kuala Lumpur Hospital, Ministry of Health Malaysia, Jalan Pahang, 50586 Kuala Lumpur, Malaysia
* Corresponding author: euweicheong@gmail.com
Received:
25
September
2024
Accepted:
15
December
2024
Introduction: Extraarticular deformity (EAD) with knee arthritis is a complex condition involving tri-planar bone deformity with pathological malalignment and chronic soft tissue contracture or laxity in the knee joint. Intraarticular correction by TKA, which was previously performed with conventional manual jig by mechanical alignment technique, had its limits and difficulties especially extensive soft tissue release and risk of jeopardizing the collateral ligaments. Robotic technology allows for reproducible and precise execution of surgical plan and allows adjustment to various new personalised alignment philosophy including functional alignment (FA). FA technique involves the adjustment of components positioning that least compromise the soft tissue envelope while restoring the limb alignment and joint obliquity to create a balanced knee. The aim is to study the outcome of intra-articular correction by robotic assisted TKA using Functional Alignment (FA) technique. Methodology: This is a single surgeon series of 8 patients with extraarticular deformity who underwent robotic assisted total knee arthroplasty (TKA) with FA technique. Soft tissue release was gradually released and followed by adjustments of implant positioning in order to achieve a balanced medio-lateral gap. Results: Postoperatively, the lower limb alignment of all patients were restored within 6° (mean 4.54°) based on functional alignment boundaries. Knee phenotype and joint line obliquity (JLO) were restored in comparison to contralateral lower limb. There were 6 varus and 2 valgus malalignment. 7 patients were implanted with posterior stabilized implants while 1 was implanted with cruciate retaining implant. Arc of knee flexion and extension improved (P = 0.002). There was a large postoperative improvement in the Knee Society Score (KSS) (P < 0.001). Discussion: Intraarticular correction by TKA for EAD with knee arthritis is technically reliable with robotic technology. It allows intraoperative adjustment following functional alignment philosophy, thereby, restoring pre-arthritic alignment, knee phenotype and joint line obliquity.
Key words: Extraarticular deformity / Functional alignment / Robotic assisted total knee arthroplasty
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.