Complications related to the revision prosthesis at two years.

CCK group RHK group P value
Complicationa 4/33 (12.1%) 12/30 (40%) 0.04
Type of complicationb
 Acute PJI 2 1 n.s.
 Aseptic loosening 0 3 n.s.
 Septic loosening 0 1 n.s.
 Extensor mechanism 0 6 0.04
 Stiffness 2 1 n.s.
 Femorotibial instability 0 1 n.s.
Re-interventionb
 DAIR 2 1 n.s.
 Arthrolysis 2 2 n.s.
 Extensor mechanism intervention 0 2 n.s.
 Re-revision with change of implant 0 6 0.008
Total 4 (12.1%) 11 (36.7%) 0.04
a

Data are presented as number of patients (proportion).

b

Complications are presented in number of occurrences. Two patients of RHK group had several consecutive complications.

PJI: prosthetic joint infection; DAIR: debridement, antibiotics, and implant retention.