Open Access

Table 1

Results obtained for the required load to rupture the tested suture configuration, including the new proposed double Mason-Allen.

Tests Actual test results
Rupture weight Load to failure Results
Error due to using 100 g weight steps
Mean load to failure ± standard deviation
(g) (N) (N) (%)
1) Simple
 Minimum 2,900 28.45 33.84 ± 5.40 3.5
 Maximum 4,000 39.24 2.5
2) Mattress
 Minimum 5,200 51.01 66.22 ± 15.21 1.9
 Maximum 8,300 81.42 1.2
3) Mason-Allen
 Minimum 14,000 137.34 145.68 ± 8.34 0.7
 Maximum 15,700 154.02 0.6
4) Modified Mason-Allen
 Minimum 15,200 149.11 159.90 ± 10.79 0.7
 Maximum 17,400 170.69 0.6
5) Double Mason-Allen
 Minimum 40,800 400.25 423.30 ± 23.05 0.2
 Maximum 45,500 446.36 0.2