Open Access
Table 1
Positioning of the implants for the study group (revision from partial to total knee) under the principles of functional alignment. Positioning of the implants with reference to the femoral and tibial mechanical axes. Rotation of the femoral implant with reference to the transepicondylar axis.
| Implants positioning | ||
|---|---|---|
| Femoral implant positioning | Valgus | 0.2 (SD = 1.28) |
| External rotation | 1.6 (SD = 1.29) | |
| Flexion | 6.2 (SD = 1.92) | |
| Tibial implant positioning | Varus | 0.38 (1.49) |
| Slope | 1.6 (SD = 0.89) | |