Issue |
SICOT-J
Volume 8, 2022
|
|
---|---|---|
Article Number | 1 | |
Number of page(s) | 8 | |
Section | Hip | |
DOI | https://doi.org/10.1051/sicotj/2021064 | |
Published online | 06 January 2022 |
Original Article
The impact of stem fixation method on Vancouver Type B1 periprosthetic femoral fracture management
1
Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK
2
Academic Orthopaedics Department, Papageorgiou General Hospital & CORE Lab at CIRI AUTH, Aristotle University Medical School, University Campus 54 124, Thessaloniki, Greece
3
Northern Institute for Cancer Research, Newcastle University, Framlington Place, Newcastle upon Tyne NE2 4HH, UK
4
DePuy Synthes, St. Anthony’s Road, Leeds LS11 8DT, UK
* Corresponding author: M.Moazen@ucl.ac.uk
Received:
10
November
2021
Accepted:
6
December
2021
Introduction: Our understanding of the impact of the stem fixation method in total hip arthroplasty (THA) on the subsequent management of periprosthetic femoral fractures (PFF) is still limited. This study aimed to investigate and quantify the effect of the stem fixation method, i.e., cemented vs. uncemented THA, on the management of Vancouver Type B1 periprosthetic femoral fractures with the same plate. Methods: Eight laboratory models of synthetic femora were divided into two groups and implanted with either a cemented or uncemented hip prosthesis. The overall stiffness and strain distribution were measured under an anatomical one-legged stance. All eight specimens underwent an osteotomy to simulate Vancouver type B1 PFF’s. Fractures were then fixed using the same extramedullary plate and screws. The same measurements and fracture movement were taken under the same loading conditions. Results: Highlighted that the uncemented THA and PFF fixation constructs had a lower overall stiffness. Subsequently, the mechanical strain on the fracture plate for the uncemented construct was higher compared to the cemented constructs. Conclusion: PFF fixation of a Vancouver type B1 fracture using a plate may have a higher risk of failure in uncemented THAs.
Key words: Total hip arthroplasty (THA) / Periprosthetic femoral fracture (PFF) / Biomechanics / Cemented / Uncemented
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.