Original Article
Early loss of radiographic reduction after acute acromioclavicular joint reconstruction: Comparison of open Double Endobutton fixation vs. Nottingham Surgilig
Department of Trauma and Orthopaedics, Luton and Dunstable University Hospital, Bedfordshire NHS Trust, Luton LU4 0DZ, UK
* Corresponding author: georgesaraglis@icloud.com
Received:
28
September
2022
Accepted:
6
November
2022
Introduction: Surgical treatment is usually recommended for the acute unstable acromioclavicular joint (ACJ) dislocations. Among the wide variety of different surgical techniques, the Double Endobutton and the Nottingham Surgilig technique are two of the most widely acceptable and well described techniques. The aim of this study was to offer a direct comparison of the above techniques in question, analysing the patients outcomes and assessing the risk of early loss of radiographic reduction. Materials and methods: A total of 48 patients who met the inclusion criteria were included in the study. Patients were categorised in two groups (Endobutton and Nottingham Surgilig group) and post operative assessment of the patients was performed using the Oxford Shoulder (OSS) and Constant Murley (CMS) scores. Patient demographics, hand dominance, ACJ classification and co-morbidities were included in the analysis and radiographic evaluation was conducted for both groups. Results: Both techniques provide a good outcome in the management of unstable ACJ dislocations but the risk of early radiographic failure remains higher in the double Endobutton technique (26% vs. 17.39% for the Nottingham Surgilig group). Factors such as patients’ demographics, hand dominance, co-morbidities and grade of ACJ separation do not seem to contribute to radiographic loss of reduction, whereas the incorrect positioning of the coracoid endobutton is a significant factor predisposing to early radiographic failure, P < 0.001. Discussion: The incidence of early loss of radiographic reduction still remains high in both groups. In order to reduce this common complication, accurate placement of the coracoid endobutton under fluoroscopic intra-operative control is strongly recommended.
Key words: Acromioclavicular joint dislocation / ACJ dislocation / Double Endobutton / Nottingham Surgilig / Tightrope system / LockDown system
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.