Case Report
Analysis of an explanted dual mobility cup after 21 years, parabolic wear pattern: A case report
1
Hospices Civils de Lyon, Hôpital Lyon Sud, Chirurgie Orthopédique et Traumatologique, 165 Chemin du Grand Revoyet, 69495 Pierre Bénite Cedex, France
2
Univ de Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, IFSTTAR, LBMC UMRT_9406, Lyon, France
3
INSA, 20 Av des Buttes de Coesmes, Rennes, France
* Corresponding author: anthony.viste@chu-lyon.fr
Received:
7
December
2022
Accepted:
26
December
2022
Case: A dual mobility cup was implanted in 1983 in a 43-year woman. After 31 years of normal function, we analysed the explanted materials with modern techniques. Conclusion: Volumetric wears of the small and large articulations of the dual-mobility construct were similar. For the first time, we demonstrated that the dual-mobility liner underwent parabolic (not linear) wear during the period of implantation.
Key words: Dual mobility / Wear / Total hip arthroplasty
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.