Excellent survival of second-generation uncemented dual mobility cups compared with first-generation cups at a minimum of 10 years follow-up in primary total hip arthroplasty
1
Department of Orthopedic Surgery, CHU Guadeloupe, Pointe à Pitre, France
2
Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, Lyon, France
3
EA 7424, Interuniversity Laboratory of Human Movement Science, Université Lyon 1, Lyon, France
4
Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622 Lyon, France
* Corresponding author: gerald.delfosse@gmail.com
Received:
20
June
2024
Accepted:
1
July
2024
Introduction: This study aimed to compare the revision rate and long-term survival between two generations of uncemented dual mobility cup (DMC) from the same manufacturer in primary total hip arthroplasty (THA) at a minimum follow-up of 10 years. Methods: This retrospective monocentric study included all THA performed with an uncemented DMC from the same company. The cohort included 150 patients with 22 first-generation DMC and 128 second-generation DMC. The coating of the second generation was a double-coating Plasma spray of Titanium and Hydroxyapatite (HAP), compared to the coating of alumina and HAP for the first generation. The mean follow-up was 14.2 ± 1.2 years. The mean age was 76.0 ± 10.1 years. The Harris hip score (HHS), complications, and revisions were collected at the last follow-up. Ten- and fifteen-year Kaplan-Meier survival was calculated. Results: At the last follow-up, the mean HHS was 83.2 ± 9.1. There were two acetabular loosenings with the old coating (9.1%) and one case with the new one (0.78%) (p = 0.056). There was one extra-prosthetic dislocation (0.67%) and one postoperative infection (0.67%). Survival without acetabular revision at 10 and 15 years was 90.9% for the 1st generation and 99.2% for the 2nd generation (p = 0.009). Conclusion: Survival without acetabular revision was significantly higher at 10 and 15 years of follow-up with the second generation of DMC with plasma-sprayed titanium and HAP coating compared to the first generation of DMC coat. The dislocation was uncommon, thanks to the dual mobility concept. This second generation of uncemented DMC can be safely used in primary THA.
Key words: Dual mobility cup / THA / Aseptic loosening / Acetabular coating
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.