Table 2
Tips and tricks for implant compatibility
Cup | The cup should be specifically designed for a dual mobility system. |
Liner | The liner used must be from the same manufacturer as the cup. The liner and cup are an inseparable combination. |
The size of the liner must be in accordance with the size of the cup; according to the manufacturer’s recommendations. | |
UHMWPE or XLPE liners may be used. Please note that no long-term studies are available on the evaluation of the XLPE in DMC. | |
Femoral head | Heads with a diameter of 22 mm are to be favored. 28 mm diameter heads should not be used with cups smaller than 54 mm. |
Femoral stem | The femoral stem used should have a thin polished neck that is trapezoid, elliptical or circular in shape. |