Issue |
SICOT-J
Volume 9, 2023
|
|
---|---|---|
Article Number | 34 | |
Number of page(s) | 6 | |
Section | Knee | |
DOI | https://doi.org/10.1051/sicotj/2023033 | |
Published online | 30 November 2023 |
Original Article
Estimated diameter increase from a 4S to a 6S hamstring graft configuration – A cadaveric study
1
Sherbrooke University, 3001 12th Avenue North, Sherbooke, QC J1H 5H4, Canada
2
Centre Hospitalier Hôtel-Dieu-de-Sorel, 400 Av. de l’Hôtel-Dieu, Sorel-Tracy, QC J3P 1N4, Canada
3
Center for Research at the CHUS (CIUSSS de l’Estrie CHUS), 3001 12th Avenue North, Sherbooke, QC J1H 5H4, Canada
4
Research center on aging (CIUSSS de l’Estrie CHUS), 1036, rue Belvédère Sud, Sherbooke, QC J1H 4C4, Canada
5
Department of Electrical Engineering and Computer Engineering, Université de Sherbrooke, 2500, boulevard de l’Université, bureau C1-3050, Sherbrooke, QC J1K 2R1, Canada
* Corresponding author: yoan.bourgeault-gagnon@usherbrooke.ca
Received:
29
June
2023
Accepted:
5
November
2023
Purpose: Graft diameter in anterior cruciate ligament reconstructions has been shown to influence the risk of failure. It is therefore important to be able to adjust the graft configuration to modify the diameter. To measure the impact of a 6-strand (6S) hamstring autograft configuration on graft diameter compared to the standard 4-strand (4S) configuration. Methods: Cadaveric study on 33 knees, using the usual hamstring graft harvesting technique. Semitendinosus and gracilis tendons were harvested and their length, width, and diameter were measured in 4S and 6S configurations separately by three evaluators. Results: 6S configuration leads to a median increase of 1.5 (range: 0.0–2.0) mm in diameter compared to 4S (p < 0.001). A graft diameter of more than 8 mm is attained in less than a third of 4S grafts within this population in comparison to 84% when the 6S configuration is used. Discussion: The 6S hamstring graft configuration increases the graft diameter by a median of 1.5 millimeters compared to the traditional 4S configuration. It can reliably be used to obtain an 8.5 mm graft diameter or more in cases where the semitendinosus measures at least 270.5 mm and the 4S configuration has a diameter of 7.5 mm or 8 mm. This information helps to better delineate the impact of a 6S configuration in a pre-operative or intra-operative setting to optimize the decisional process and surgical flow and to easily adapt the graft diameter.
Level of evidence: V (cadaveric study)
Key words: ACL reconstruction / Anterior cruciate ligament / Hamstring graft / Cadaveric study
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abbreviations
ACL: Anterior cruciate ligament
BPTB: Bone-patellar tendon-bone graft
Introduction
The failure rate of anterior cruciate ligament (ACL) reconstructions remains high, between 0.7% and 20% [1]. The main factors related to an increased risk of revision can be grouped into biological, traumatic, or technical causes and include, among others, patient age, compliance with postoperative protocol, type of sport, tunnel placement, type of graft, graft diameter, and absence of associated lateral extra-articular reconstruction [1–6].
Historically, patellar tendon grafts (BPTB) were considered the gold standard, but hamstring grafts are now the most popular option internationally [7]. Their primary advantages are smaller incisions, a lower risk of anterior knee pain, and a high load-to-failure. Conversely, their main potential drawbacks are residual hamstring weakness, risk of saphenous nerve injury, difficulty in predicting graft size, and a potentially longer maturation time [8, 9]. This last factor is the one this project is based on since being able to adapt intra-operatively is crucial. It is important to consider the length and size of the harvested semitendinosus and gracilis tendons in order to obtain a graft of adequate diameter, as this influences its biomechanical properties [10, 11]. Graft diameter larger than 8 mm seems to be associated with a lower risk of failure and better functional results [2–4], as shown in the meta-analysis done by Conte et al. who found a relative risk of failure 6.8 times greater for grafts equal or less than 8 mm in diameter [3]. In addition, Spragg et al. demonstrated a reduction in the relative risk of failure of 15% per 0.5 mm increase in graft diameter [12, 13].
Classically, a 4-strand configuration (4S) has been used for every case, but a substantial proportion of grafts would not reach a diameter above 8 mm. Techniques have been subsequently described to increase graft size when appropriate. Depending on graft length, size, and specific patient’s characteristics, surgeons can decide whether to use a hybrid allograft/autograft [14], a partial width quadriceps tendon augmentation [15, 16] or, most commonly, modify the graft configuration to obtain a 5-strand (5S) or 6-strand (6S) hamstring autograft configuration [17].
To optimize graft diameter while not significantly affecting the surgical flow, multiple authors have established that the cross-sectional area of the hamstring tendons on a pre-operative magnetic resonance imaging (MRI) is significantly correlated with the intra-operative 4S graft size and can be used to refine surgical planning [3, 18]. Similar correlations have been shown for pre-operative anthropometric parameters like height, age, thigh diameter and length, and gender [3, 19, 20]. We propose that an adjunctive pre-operative and intra-operative predictive tool, designed to estimate the potential increase in diameter from changing a 4S to a 6S configuration, could be useful. This tool would either confirm the planned graft choice or allow for last-minute adjustments. Specifically, if pre-operative MRI measurements of the hamstring or intra-operative measurements of a 4S graft indicate an insufficient diameter, the calculated 4S-to-6S increment value could inform the decision on whether to proceed with the conversion or opt for an alternative augmentation method.
The objective of this descriptive cadaveric study was to measure the impact that a 6S configuration has on graft diameter compared to a 4S configuration. The hypothesis was that this technique reliably increases the diameter of the graft by more than 1 mm. The secondary objective was to establish the minimal semitendinosus length and 4S diameter necessary to reliably obtain 6S grafts with a diameter larger than 8 mm, i.e. 8.5 mm or more, and a length of 90 mm or more, considered as a safe minimum length for proper tibial fixation. Finally, intra-rater and inter-rater reliability were evaluated on diameter measures of 4S grafts.
Methods
The protocol of this descriptive cadaveric study was approved by the local ethical committee. Between January and March 2019, 17 specimens were prepared according to the usual technique for fresh corpse preservation, without embalming. Thirty-four cadaveric knees were dissected by an orthopedic surgery senior resident. Inclusion criteria consisted of every cadaver that had previously given written consent to donate their body to science. Exclusion criteria included any previous surgery on the hamstring tendons or damaged tendons rendering them unusable for manipulation. No power analysis was performed; every specimen available during the data collection period was used, which was of the same magnitude as both previous studies of the subject (n = 23 [21] and n = 61 [22]).
Each tendon was harvested by the same senior resident using the usual semitendinosus and gracilis harvesting technique, as described thoroughly in a previous publication [15]. A tendon harvester for cruciate ligament reconstruction (Conmed Linvatec, Aurora, Ohio) was used through an oblique anteromedial incision to harvest both tendons after freeing them from their adherences and keep as much length as possible by dissecting the insertion subperiosteally. Each pair of tendons was then stored in a freezer until all the specimens were ready to be used. Measurements were completed after two measuring sessions. The frozen tendons were gradually thawed at room temperature and kept moist in a surgical sponge dampened with normal saline throughout the entire session. The gracilis and semitendinosus tendons were straightened and deposited on the table and then measured in length and width with a millimetric graduated ruler. The orientation of one of them was flipped head-to-tail to uniformize graft diameter before being folded on a high-size PDS suture, corresponding to the in vivo technique for the 4S graft configuration (Figure 1). 4S grafts’ length and diameter were measured.
Figure 1 Illustration of semi-tendinosis (dark grey) and gracilis (light grey) tendons in 4S (A) and 6S (B) graft configurations used for diameter measurements. A: 4S configuration representing the initial diameter measurement before whipstitching. Both tendons are folded over a PDS suture before diameter measurement. B: 6S configuration representing the final graft diameter measurement. 4S graft is unfolded and both tendons are sutured together with a resorbable polyfilament suture (blue). The graft is then folded in 3 equal parts over a resorbable poly filament suture (black). Both ends are whipstitched and tabularized with a resorbable poly filament 2-0 suture (green) before diameter measurement. |
The two tendons were unfolded and whipstitched together at one end with a resorbable polyfilament 2-0 suture. They were folded in three over a resorbable poly filament size 1 suture before being whipstitched and tubularized at both extremities with a resorbable polyfilament 2-0 suture to constitute the 6S graft (Figure 1). The 2-0 suture was considered small enough so it would not affect significatively the diameter measurement. 6S grafts’ length and diameter were measured.
Lengths and widths of all tendons and grafts were measured with a standard millimetric graduated ruler. Diameters of the 4S and 6S grafts were measured with a Conmed Sizing Tube set (Conmed Linvatec, Aurora, Ohio) ranging from 6.5 to 11 mm in increments of 0.5 mm. In order to represent as accurately as possible the in-vivo technique used in our center, tendons and grafts were not pre-tensioned before being measured in length and diameter, other than the usual manual traction needed to pass the graft through the sizing tubes. The strength needed to pull grafts through the tubes was left to the surgeon’s judgment to reflect in vivo reality. As a general principle, when deciding between sizes, surgeons evaluated which graft would optimally fill a tunnel of the size measured, without being unreasonably hard to pull through.
Lengths, widths, and diameters in 4S and 6S configurations were measured independently by three different evaluators (two fellowship-trained sports medicine surgeons and one senior resident), in order to evaluate the inter-observer reliability. Ten 4S grafts were also randomly and blindly re-evaluated in different sessions by each evaluator in order to establish the intra-observer reliability of sizing tube measurements. Blinding was achieved by having the research assistant randomly select the ten grafts to be reassessed, without the observers being aware of which grafts were chosen.
Statistical calculations and analyses were done by a statistician with SPSS (v23.0.0 from IBM). Descriptive statistics were used for the calculation of means, medians, proportions, and confidence intervals. Median values obtained for each sample from the three evaluators were used for diameter calculations, whereas means of the three evaluators’ measures were used for length and width calculations. A Shapiro-Wilk Test was used to assess the normality of the variables. A two-tailed Wilcoxon Signed-Rank Test was used to compare the 4S and 6S graft diameters since both were paired and were considered ordinal variables in the context of this study. A statistical significance threshold of 0.05 was used. Inter and intraobserver reliability of graft diameter measures was evaluated with the help of Kendall’s coefficient of concordance, which allows evaluation of the concordance of discrete ordinal measures.
The whole dataset has been published in an open-access data repository [23].
Results
Thirty-three of the 34 dissected knees were deemed usable for the study. One knee was excluded because of damage caused to the graft while being harvested. Demographic characteristics of the 17 cadavers have been tabulated (Table 1).
Demographic characteristics.
Characteristics of the harvested semitendinosus and gracilis tendon are as follow: the semitendinosus tendons had a mean length of 300.9 (SD = 31.6) mm and a width of 6.1 (SD = 0.9) mm, whereas the gracilis tendons had a mean length of 269.4 (SD = 24.4) mm and a width of 4.3 (SD = 0.7) mm.
The mean length of 4S grafts is 143.6 mm (SD = 15.0) and all of them were over 90 mm long. The mean length of 6S grafts is 96.3 mm (SD = 10.3) and 72.7% of them reached the desired length of 90 mm. A minimum semitendinosus length of 253 mm (sensitivity 0.949, specificity 1.000) was required to reliably obtain a 6S graft length of 80, whereas a semitendinosus length of 270.5 mm (sensitivity 0.946, specificity 0.7508) was required to reliably obtain a 6S graft length of at least 90 mm.
Within this population, 69.7% of grafts would not measure more than 8 mm in a 4S configuration, with this proportion dropping to 15.2% in a 6S configuration (Table 2).
4S and 6S grafts diameters distribution.
Medians (range) were used to describe graft diameters since both were paired ordinal variables, and 4S graft diameter data did not follow a normal distribution (Shapiro-Wilk = 0.874, p = 0.0012). The median diameter of 4S grafts is 8.0 (range: 7.0–9.0) mm versus 9.0 (range: 7.5–10.5) mm for the 6S grafts, which translates to a 1.5 (range: 0.0–2.0) mm median increase in diameter. The 6S graft configuration significantly increased graft diameter (p < 0.001). After being folded in 3, 78.3% of all grafts with a diameter initially considered insufficient reached a size larger than 8 mm. This percentage increases to 92.9% if we consider only those with an initial diameter of 7.5–8.0 mm (Table 3).
Diameter increase with 6S configuration.
Inter-rater and intra-rater reliability of diameter measure on 4S grafts, were excellent, with concordances of 0.904 (p < 0.001) and 0.917 (p < 0.001), respectively.
Discussion
These results confirm that using a 6S configuration for hamstring grafts consistently and significantly increases the diameter of the graft by a median of 1.5 mm when compared to a 4S configuration. In order to be able to use these results during the per-operative decision-making process, we described the impact of this change in graft configuration using a technique as close as possible to the in-vivo surgical technique.
No other study, to the best of our knowledge, looked at the change in diameter between 4S and 6S configurations. However, our data is consistent with recent studies comparing the average diameter between 4S and 5S grafts. Walczak et al. [21] found a mean increase in diameter of 0.99 mm, whereas Krishna et al. [22] reported a 1.4 ± 0.3 mm in their randomized clinical trial when changing from a 4S to a 5S. In this latter study, the proportion of 5S grafts exceeding 8 mm was 75% while it is 78% in our 6S configuration.
As detailed in the introduction, many studies have shown better biomechanical and clinical results with bigger graft diameters [2–4, 12, 13]. For example, Conte et al. [3] have stated in their 2014 systematic review that grafts of more than 8 mm in diameter are protective against rupture, mainly based on Magnussen et al. [2] and Mariscalco et al. [4] papers. None of the studies comparing functional and clinical outcomes between ACL reconstructions done with 4S and 5S/6S grafts found any difference. Therefore, they concluded that the 5S or 6S configurations remain safe options in case of smaller tendons [24, 25].
Given this information, we wanted to determine the percentage of grafts that reached a diameter of more than 8.0 mm (i.e., minimum 8.5 mm threshold). We found that 78.3% of 4S grafts with a diameter of 8.0 mm or less reached 8.5 mm or more when the 6S configuration was used. This proportion increased to 92.9% if we considered only the 4S grafts of 7.5 or 8 mm, meaning that this 7.5 mm cutoff could be used in an intra-operative decisional algorithm to drive the surgeon into the 6S configuration if a diameter of at least 8.5 mm is desired. It is worth noting that one must be cautious from blindly aiming for a graft of 8.5 mm or more as some knees are smaller and have narrower intercondylar notches. A graft of too large a diameter could lead to impingement and loss of an extension [26]. The prediction of increase in diameter shown in our study could also help to avoid choosing a configuration that could lead to overstuffing of the notch.
The length of tendons also plays a role in this decisional process. The desired graft length changes depending on surgical technique but usually varies between 80 mm [27] and 90 mm for surgeons who use interference screw fixation in the tibia. A cutoff semitendinosus length of 270.5 mm can be used if a 6S graft length of 90 mm is desired and 253 mm for an 80 mm graft length. In scenarios where semitendinosus tendon length would be insufficient, other configuration techniques, like quadricipital tendon supplementation [15], could be used instead of 6S.
Limitations
The fact that this study is based on cadavers and that the mean age of the donors does not represent the usual ACL tear population can diminish the clinical applicability of its results, mainly when looking at the proportion of initial tendon sizes. The absolute diameter of the tendons used can differ from the one in our aimed population because of age and preservation process. However, since this study measures relative increases in graft diameter values between specific 4S graft diameters and their 6S configuration’s diameter, we believe that the age or sex of the population has a minimal impact on the ability to properly answer the research question.
The total number of samples (n = 33) directly limits the numbers per group and might therefore influence the external validity of the experiment. Several questions, such as the complications associated with the technique as well as the real clinical benefit, have not been evaluated and are beyond the scope of this project. As an example, the type of fixation on the femoral side might have an impact on the biomechanical properties of 5S and 6S grafts, as Snow et al. [28] have shown and must be accounted for.
The use of sizing tubes instead of a caliper to measure diameters, as well as the distribution of the data, has forced the use of medians instead of means since the variable was discrete and not normally distributed. The decision to use sizing tubes was taken in order to replicate as closely as possible the in-vivo surgical technique.
Finally, lengths, widths, and diameters were measured in a non-blinded manner and without clearly stated guidelines in regard to the tension needed to pass the graft through the sizing tubes. We tried to minimize the risk of measurement bias by asking two surgeons who specialized in sports surgery and one senior resident to repeat every measure individually, under the supervision of a research assistant. The excellent inter-rater and intra-rater reliability of diameter measurement with sizing tubes of 0.904 (p < 0.001) and 0.917 (p < 0.001) confirm the minimal effect of this possible bias.
Conclusion
The 6S hamstring graft configuration increases the graft diameter by a median of 1.5 mm compared to the traditional 4S configuration. It can reliably be used to obtain grafts larger than 8 mm and a length of 90 mm in cases where the semitendinosus measures at least 275 mm and the 4S configuration has a diameter of 7.5 or 8 mm.
Conflict of interest
Sonia Bédard, Frédéric Balg, François Vézina and Yoan Bourgeault-Gagnon report an unrestricted grant to the research foundation of the of the university’s orthopaedic surgery program by DepuySynthes, a Johnson and Johnson company, Wright Medical Technology inc and Zimmer Biomet. Other authors certify that they have no potential financial conflict of interest.
Funding
This study was internally funded by the research foundation of the university’s orthopedic surgery program.
Ethical approval
The protocol of this descriptive cadaveric study was approved by the local ethical committee.
Informed consent
Every cadaver used for specimen harvesting had previously given written consent to donate their body to science.
Authors’ contribution
-
YBG: Data collection, Helped interpreting the results, Final manuscript writing.
-
AKL: Study design, Specimen harvesting, Data collection, Draft manuscript preparation, Final manuscript review.
-
SB: Data collection, Project administration, Final manuscript review.
-
KL: Statistical analysis, Helped interpret the results.
-
FB: Data collection, Helped interpret the results, Final manuscript review.
-
FV: Data collection, Conceptualization, Supervision, Final manuscript review.
All authors discussed the results and contributed to the final manuscript.
Acknowledgments
Special thanks to CB, SP, and DB, technicians in the anatomy laboratory, who helped us greatly with the preservation and preparation of samples. We would also like to thank CR, who helped with data collection.
References
- Elfekky M, Mostafa H, Shahi U, et al. (2022) Causes of anterior cruciate ligament reconstruction failure: a meta-analysis. J Musculoskelet Surg Res 6, 193–199. [CrossRef] [Google Scholar]
- Magnussen RA, Lawrence JTR, West RL, et al. (2012) Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy 28, 526–531. [CrossRef] [PubMed] [Google Scholar]
- Conte EJ, Hyatt AE, Gatt CJ, Dhawan A (2014) Hamstring autograft size can be predicted and is a potential risk factor for anterior cruciate ligament reconstruction failure. Arthroscopy 30, 882–890. [CrossRef] [PubMed] [Google Scholar]
- Mariscalco MW, Flanigan DC, Mitchell J, et al. (2013) The influence of hamstring autograft size on patient-reported outcomes and risk of revision after anterior cruciate ligament reconstruction: a multicenter orthopaedic outcomes network (MOON) cohort study. Arthroscopy 29, 1948–1953. [CrossRef] [PubMed] [Google Scholar]
- Salmon L, App B, Sci V, et al. (2005) Incidence and Risk Factors for Graft Rupture and Contralateral Rupture After Anterior Cruciate Ligament Reconstruction. Arthroscopy 21, 948–957. [CrossRef] [PubMed] [Google Scholar]
- Getgood AMJ, Bryant DM, Litchfield R, et al. (2020) Lateral extra-articular tenodesis reduces failure of hamstring tendon autograft anterior cruciate ligament reconstruction: 2-year outcomes from the STABILITY study randomized clinical trial. Am J Sports Med 48, 285–297. [CrossRef] [PubMed] [Google Scholar]
- Chechik O, Amar E, Khashan M, et al. (2013) An international survey on anterior cruciate ligament reconstruction practices. Int Orthop 37, 201–206. [CrossRef] [PubMed] [Google Scholar]
- Baawa-Ameyaw J, Plastow R, Begum FA, et al. (2021) Current concepts in graft selection for anterior cruciate ligament reconstruction. EFORT Open Rev 6, 808–815. [CrossRef] [PubMed] [Google Scholar]
- Papageorgiou CD, Ma CB, Abramowitch SD, et al. (2001) A multidisciplinary study of the healing of an intraarticular anterior cruciate ligament graft in a goat model. Am J Sports Med. 29 (5): 620–626. [CrossRef] [PubMed] [Google Scholar]
- Hamner DL, Brown CH, Steiner ME, et al. (1999) Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: Biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg Am 81, 549–557. [CrossRef] [PubMed] [Google Scholar]
- Boniello MR, Schwingler PM, Bonner JM, et al. (2015) Impact of hamstring graft diameter on tendon strength: a biomechanical study. Arthroscopy 31, 1084–1090. [CrossRef] [PubMed] [Google Scholar]
- Snaebjörnsson T, Hamrin Senorski E, Ayeni OR, et al. (2017) Graft diameter as a predictor for revision anterior cruciate ligament reconstruction and KOOS and EQ-5D values A cohort study from the Swedish National Knee Ligament Register based on 2240 patients thorkell. Am J Sports Med 45, 2092–2097. [CrossRef] [PubMed] [Google Scholar]
- Spragg L, Chen J, Mirzayan R, et al. (2016) The effect of autologous hamstring graft diameter on the likelihood for revision of anterior cruciate ligament reconstruction. Am J Sports Med 44, 1475–1481. [CrossRef] [PubMed] [Google Scholar]
- Pennock AT, Ho B, Parvanta K, et al. (2017) Does allograft augmentation of small-diameter hamstring autograft ACL grafts reduce the incidence of graft retear? Am J Sports Med 45, 334–338. [CrossRef] [PubMed] [Google Scholar]
- Bourgeault-Gagnon Y, Leang AK, Bédard S, et al. (2022) A partial-thickness quadriceps autograft reliably augments the size of the hamstring graft during anterior cruciate ligament reconstruction. Arthrosc Sports Med Rehabil 4, e2005–e2009. [CrossRef] [PubMed] [Google Scholar]
- Wilson WK, Morris R, Coskey A, et al. (2019) Quadriceps augmentation of undersized hamstrings during ACL reconstruction. Knee 26, 73–78. [CrossRef] [PubMed] [Google Scholar]
- Nazari G, Barton KI, Bryant D, et al. (2021) Five- and six-strand hamstring grafts consistently produce appropriate graft diameters for anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 29, 2940–2947. [CrossRef] [PubMed] [Google Scholar]
- Bickel BA, Fowler TT, Mowbray JG, et al. (2008) Preoperative magnetic resonance imaging cross-sectional area for the measurement of hamstring autograft diameter for reconstruction of the adolescent anterior cruciate ligament. Arthroscopy 24, 1336–1341. [CrossRef] [PubMed] [Google Scholar]
- Goyal S, Matias N, Pandey V, Acharya K (2016) Are pre-operative anthropometric parameters helpful in predicting length and thickness of quadrupled hamstring graft for ACL reconstruction in adults? A prospective study and literature review. Int Orthop 40, 173–181. [PubMed] [Google Scholar]
- Pinheiro LFB, de Andrade MAP, Teixeira LEM, et al. (2011) Intra-operative four-stranded hamstring tendon graft diameter evaluation. Knee Surg Sports Traumatol Arthrosc 19, 811–815. [CrossRef] [PubMed] [Google Scholar]
- Walczak BE, Hetzel SJ, Akoh CC, Baer GS (2021) Intra-operative conversion to a five-strand hamstring autograft configuration significantly increases anterior cruciate ligament graft diameter independent of patient characteristics. J Knee Surg 34, 828–833. [CrossRef] [PubMed] [Google Scholar]
- Krishna L, Panjwani T, Ren Mok Y, et al. (2018) Use of the 5-strand hamstring autograft technique in increasing graft size in anterior cruciate ligament reconstruction. Arthroscopy 34, 2633–2640. [CrossRef] [PubMed] [Google Scholar]
- Bourgeault-Gagnon Y (2023) Data diameter increase 4S to a 6S HS graft configuration. Mendeley Data. https://doi.org/10.17632/8HNPSC43MZ.1. [Google Scholar]
- Calvo R, Figueroa D, Figueroa F, et al. (2017) Five-strand hamstring autograft versus quadruple hamstring autograft with graft diameters 8.0 millimeters or more in anterior cruciate ligament reconstruction: clinical outcomes with a minimum 2-year follow-up. Arthroscopy 33 (5): 1007–1013. [CrossRef] [PubMed] [Google Scholar]
- Attia AK, Nasef H, ElSweify KH, et al. (2020) Failure rates of 5-strand and 6-strand vs. quadrupled hamstring autograft ACL reconstruction: a comparative study of 413 patients with a minimum 2-year follow-up. Orthop J Sports Med 8, 1–7. https://doi.org/10.1177/2325967120946326. [CrossRef] [Google Scholar]
- Fujimaki Y, Thorhauer E, Sasaki Y, et al. (2016) Quantitative in situ analysis of the anterior cruciate ligament. Am J Sports Med 44, 118–125. [CrossRef] [PubMed] [Google Scholar]
- Krishna L, Panjwani T, Mok YR, et al. (2018) Use of the 5-strand hamstring autograft technique in increasing graft size in anterior cruciate ligament reconstruction. Arthroscopy 34, 2633–2640. [CrossRef] [PubMed] [Google Scholar]
- Snow M, Cheung W, Mahmud J, et al. (2012) Mechanical assessment of two different methods of tripling hamstring tendons when using suspensory fixation. Knee Surg Sports Traumatol Arthrosc 20, 262–267. [CrossRef] [PubMed] [Google Scholar]
Cite this article as: Bourgeault-Gagnon Y, Leang AK, Bédard S, Lebel K, Balg F & Vézina F (2023) Estimated diameter increase from a 4S to a 6S hamstring graft configuration - A cadaveric study. SICOT-J 9, 34
All Tables
All Figures
Figure 1 Illustration of semi-tendinosis (dark grey) and gracilis (light grey) tendons in 4S (A) and 6S (B) graft configurations used for diameter measurements. A: 4S configuration representing the initial diameter measurement before whipstitching. Both tendons are folded over a PDS suture before diameter measurement. B: 6S configuration representing the final graft diameter measurement. 4S graft is unfolded and both tendons are sutured together with a resorbable polyfilament suture (blue). The graft is then folded in 3 equal parts over a resorbable poly filament suture (black). Both ends are whipstitched and tabularized with a resorbable poly filament 2-0 suture (green) before diameter measurement. |
|
In the text |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.