Issue |
SICOT-J
Volume 6, 2020
Special Issue: "HIP and KNEE Replacement" Guest Editors: C Batailler, S Lustig, J Caton
|
|
---|---|---|
Article Number | 30 | |
Number of page(s) | 6 | |
Section | Hip | |
DOI | https://doi.org/10.1051/sicotj/2020027 | |
Published online | 04 August 2020 |
Original Article
Early low complication rate of ceramic-on-ceramic total hip arthroplasty by direct anterior approach
1
Department of Orthopaedic Surgery, Lyon North University Hospital, Lyon, France
2
Department of Orthopaedic Surgery, Western Health, Melbourne, Australia
3
Australian Institute for Musculoskeletal Science (AIMSS), The University of Melbourne and Western Health, St. Albans, VIC, Australia
*Corresponding author: cecile-batailler@hotmail.fr
Received:
8
July
2020
Accepted:
21
July
2020
Introduction: Ceramic-on-ceramic couplings are an alternative bearing surface to reduce the problems related to polyethylene wear and debris. However, ceramic articulations have their own risk of unique complications: fracture, squeaking, or dislocation. Few studies have assessed the outcomes of ceramic-on-ceramic total hip arthroplasties (THA) by direct anterior approach (DAA). The aim was to evaluate the early complications and revision rate of ceramic-on-ceramic THA by DAA. Material: A retrospective single-center study of 116 consecutive THAs was performed by DAA (106 patients) with ceramic-on-ceramic bearing from January 2015 to February 2018 with a minimum 24 months of follow-up. No patients were lost to follow-up. The mean age was of 55.3 years ± 11.3. The same cementless acetabular shell with a Biolox Delta ceramic insert and head were used. The complication and revision rates were collected at the last follow-up. The positioning of the acetabular implant was assessed on standard radiographs. Postoperative clinical outcomes were assessed by the Harris Hip Score. Results: At a mean follow-up of 31.9 months ± 5.5, no THA was revised. Five patients had late complications: 3 squeaking (2.6%) and 2 psoas impingements (1.7%) and were managed conservatively. All patients had satisfactory bony ingrowth of acetabular component, with no radiolucent lines and no osteolysis. Eight patients (6.9%) had an anterior overhang of the cup. The mean overhang for these patients was 4.1 mm. 111 hips (96%) were perceived as forgotten or having no limitations. Conclusion: This ceramic-on-ceramic coupling and shell by DAA produced excellent clinical outcomes and implant survival rate at a minimum two-year follow-up study. No serious complication was observed during the follow-up.
Key words: Total hip arthroplasty / Acetabular cup / Ceramic-on-ceramic / Complications / Direct anterior approach
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.