Open Access
Issue
SICOT-J
Volume 8, 2022
Article Number 32
Number of page(s) 8
Section Hip
DOI https://doi.org/10.1051/sicotj/2022032
Published online 15 August 2022
  1. Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet. 370, 1508–1519. [Google Scholar]
  2. Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years follow up. Orthop Traumatol Surg Res 97, 8–13. [CrossRef] [PubMed] [Google Scholar]
  3. Delaunay C, Hamadouche M, Girard J, Duhamel A (2013) What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471, 3863–3869. [CrossRef] [PubMed] [Google Scholar]
  4. Lehil MS, Bozic KJ (2014) Trends in total hip arthroplasty implant utilization in the United States. J Arthroplasty 29(10), 1915–1918. [CrossRef] [PubMed] [Google Scholar]
  5. Tonino AJ, Rahmy AIA (2000) The hydroxyapatite-ABG hip system: 5- to 7-Year results from an international multicentre study. J Arthroplasty 15(3), 274–282. [CrossRef] [PubMed] [Google Scholar]
  6. Blacha J (2004) High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses 65 hips in 56 young patients followed for 5–9 years. Acta Orthop Scand 75(3),: 276–282. [CrossRef] [PubMed] [Google Scholar]
  7. Bidar R, Kouyoumdjian P, Munini E, Asencio G (2009) Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years. Orthop Traumatol Surg Res 95(8), 579–587. [CrossRef] [PubMed] [Google Scholar]
  8. Baker PN, McMurtry IA, Chuter G, Port A, Anderson J (2009) THA with the ABG I prosthesis at 15 years: excellent survival with minimal osteolysis. Clin Orthop Relat Res 468(7), 1855–1861. [Google Scholar]
  9. Herrera A, Mateo J, Lobo-Escolar A, Panisello JJ, Ibarz E, Gracia L (2013) Long-term outcomes of a new model of anatomical hydroxyapatite-coated hip prosthesis. J Arthroplasty 28(7), 1160–1166. [CrossRef] [PubMed] [Google Scholar]
  10. D’Aubigné RM, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Jt Surg Am 36(3), 451–475. [CrossRef] [PubMed] [Google Scholar]
  11. Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. J Bone Jt Surg Am 51(4), 737–755. [CrossRef] [PubMed] [Google Scholar]
  12. DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121, 20–32. [Google Scholar]
  13. Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141, 17–27. [Google Scholar]
  14. Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Jt Surg Am 72(4), 518–528. [CrossRef] [PubMed] [Google Scholar]
  15. Brooker AF, Bowerman JW, Robinson RA, Riley LH (1973) Ectopic Ossification Following Total Hip Replacement. J Bone Jt Surg Am 55(8), 1629–1632. [CrossRef] [PubMed] [Google Scholar]
  16. Kaplan EL, Meier P (1958) Nonparametric Estimation from Incomplete Observations. J Am Stat Assoc 53(282), 457–481. [CrossRef] [Google Scholar]
  17. Epinette JA, Manley MT (2014) No differences found in bearing related hip survivorship at 10–12 years follow-up between patients with ceramic on highly cross-linked polyethylene bearings compared to patients with ceramic on ceramic bearings. J Arthroplasty 29(7), 1369–1372. [CrossRef] [PubMed] [Google Scholar]
  18. Castoldi F, Rossi R, La Russa M, Sibelli P, Rossi P, Ranawat AS (2007) Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty. J Arthroplasty 22(3), 363–368. [CrossRef] [PubMed] [Google Scholar]
  19. Nourissat C, Essig J, Asencio G (2013) The cementless Anatomic Benoist Girard (ABG) II total hip arthroplasty: a minimum 8-year follow-up study. J Arthroplasty 28(4), 707–711. [CrossRef] [PubMed] [Google Scholar]
  20. Ferreira A, Aslanian T, Dalin T, Picaud J (2017) Ceramic bearings with bilayer coating in cementless total hip arthroplasty. A safe solution. A retrospective study of one hundred and twenty six cases with more than ten years’ follow-up. Int Orthop 41(5), 893–899. [CrossRef] [PubMed] [Google Scholar]
  21. Catanach MJM, Sorial RM, Eslick GD (2015) Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis. ANZ J Surg 85(4), 255–259. [CrossRef] [PubMed] [Google Scholar]
  22. Thien TM, Chatziagorou G, Garellick G, Furnes O, Havelin LI, Mäkelä K (2014) Periprosthetic femoral fracture within two years after total hip replacement. J Bone Jt Surg Am 96(19), e167. [CrossRef] [PubMed] [Google Scholar]
  23. van Loon J, Vervest AMJS, van der Vis HM, et al. (2021) Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up. Int Orthop 45(6), 1447–1454. [CrossRef] [PubMed] [Google Scholar]
  24. Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L (2002) Alumina-on-alumina total hip arthroplasty. J Bone Jt Surg Am 84(1), 69–77. [CrossRef] [PubMed] [Google Scholar]
  25. Affatato S, Traina F, Fine MD, Carmignato S, Toni A (2012) Alumina-on-alumina hip implants: a wear study of retrieved components. J Bone Joint Surg Br 1, 37–42. [CrossRef] [Google Scholar]
  26. Tozun IR, Ozden VE, Dikmen G, Beksac B (2014) Mid-term result of ceramic bearings in total hip arthroplasty. Int Orthop 38(10), 2027–2031. [CrossRef] [PubMed] [Google Scholar]
  27. Kim YH, Park JW, Kulkarni SS, Kim YH (2013) A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty. Int Orthop 37(11), 2131–2137. [CrossRef] [PubMed] [Google Scholar]
  28. Van der Wal BC, Rahmy A, Grimm B, Heyligers I, Tonino A (2008) Preoperative bone quality as a factor in dual-energy X-ray absorptiometry analysis comparing bone remodelling between two implant types. Int Orthop 32(1), 39–45. [CrossRef] [PubMed] [Google Scholar]
  29. Kim Y-H, Choi Y, Kim J-S (2010) Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis. Int Orthop 34(8), 1123–1127. [CrossRef] [PubMed] [Google Scholar]
  30. Gracia L, Ibarz E, Puértolas S, Cegoñino J, López-Prats F, Panisello JJ (2010) Study of bone remodeling of two models of femoral cementless stems by means of DEXA and finite elements. Biomed Eng OnLine 28(9), 22. [CrossRef] [PubMed] [Google Scholar]
  31. Aro HT, Alm JJ, Moritz N, Mäkinen TJ, Lankinen P (2012) Low BMD affects initial stability and delays stem osseointegration in cementless total hip arthroplasty in women. Acta Orthop 83(2), 107–114. [CrossRef] [PubMed] [Google Scholar]
  32. Hailer NP, Lazarinis S, Mäkelä KT, Eskelinen A, Fenstad AM, Hallan G (2015) Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty! Acta Orthop 86(1), 18–25. [CrossRef] [PubMed] [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.