Issue |
SICOT-J
Volume 8, 2022
|
|
---|---|---|
Article Number | 32 | |
Number of page(s) | 8 | |
Section | Hip | |
DOI | https://doi.org/10.1051/sicotj/2022032 | |
Published online | 15 August 2022 |
Original Article
Clinical results at 10 years of minimum follow-up with the ABG 2 hip arthroplasty, matched with ceramic-on-ceramic bearings
1
University Hospital of Nîmes, Rue du Pr. Robert Debré, 30029 Nimes cedex 9, France
2
Clinique Médipole-Garonne, 45, rue Gironis, 31036 Toulouse cedex 1, France
3
Laboratory of Mechanics and Civil Engineering (LMGC), CNRS-UM1, 860 Rue de St-Priest, 34090 Montpellier, France
4
Université Montpellier 1, 2 Rue de l’École de Médecine, 34090 Montpellier, France
* Corresponding author: coulomb.remy@neuf.fr
Received:
15
March
2022
Accepted:
27
June
2022
Introduction: The current study aimed as a primary goal is to assess the results of a ceramic-on-ceramic (CoC) bearing hip system matched with ABG (Anatomic Benoist Girard) 2 components in terms of survivorship. Secondary objectives addressed specifically ceramic-related complications as well as specific patterns at the bone-implant interface. Material and methods: This is a retrospective bicentric continuous series involving 147 patients (95 males vs. 52 females) who underwent ABG 2 arthroplasties with CoC bearings. One hundred and twenty-five hips were closely followed-up at a mean period of 11.3 years. Results and discussion: With a mean follow-up of 11.3 years, nine cases (5.7%) underwent revision surgery, four caused by acetabular aseptic loosening, three by deep infections, one ceramic head fracture, and one femoro-acetabular impingement. The global survivorship was 92.2% at 12.7 years. The Harris Hip Score (HHS) mean scores increased post-operatively from 50.1 up to 96.1 points (p < 0.001). All stems featured patterns of radiological osseous integration onto the hydroxyapatite (HA)-coated zones. No radiological wear or osteolysis of ceramic bearings was demonstrated however, five patients reported hip squeaking using this bearing. This study demonstrated excellent results at mid-term follow-up in patients younger than 70 years of age using cementless ABG 2 components coupled with CoC bearings with no increase in complication rate.
Key words: THR / Hip arthroplasty / Uncemented / ABG II / ABG 2 / Hydroxyapatite coating / HA
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.