Open Access
Issue
SICOT-J
Volume 4, 2018
Article Number 38
Number of page(s) 6
Section Spine
DOI https://doi.org/10.1051/sicotj/2018020
Published online 07 September 2018

© The Authors, published by EDP Sciences, 2018

Licence Creative CommonsThis is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Introduction

Disc herniation is one of the most common spine disorders and cause of 300 000 surgeries annually in the U.S. [1]. While partial discectomy has good effect on acute leg pain, long-term results reveal a reoperation rate of approximately 25% [2] with many patients suffering from low back pain years after surgery [3]. This is a clear incentive to improve the existing surgical treatment.

Low back pain is a multifactorial disorder with changing mechanical conditions in the motion segments as one of the suggested etiologies [4,5]. The intervertebral disc (IVD) is an important component of spinal stability, and in case of degeneration, the motion segment becomes unstable [6]. When the annulus tears and disc herniation occur, the integrity of the annulus fibrosus (AF) and the segmental stability are further affected. An important goal in the treatment of a herniated disc must therefore be to restore the IVD function and stability of the motion segment.

Partial discectomy is a common treatment for disc herniation. But as the defect in AF is left untreated, reherniation can occur with more nucleus pulposus (NP) tissue being pushed through the defect. To avoid this, surgeons often remove as much of the NP as possible. This prevents reherniation but an important functional part of the IVD is lost and the stability of the motion segment is prone to further deterioration. Consequently, a viable approach to NP replacementor regeneration and restoration of the mechanical properties is heavily researched [79]. There is a consensus that in order to repair the IVD, the AF should be intact [10,11] lest the NP is squeezed out through the old defect.

An ideal solution would be to close the defect and restore stability simultaneously with removal of the herniation. This would prevent reherniation and on longer-term allow restoration of native AF tissue to enable replacement or regeneration of the NP. This requires a method that provides mechanical stability and allows for biointegration with AF. There can be advantages from using tissue-engineered scaffolds for AF repair. Scaffolds are often porous and designed to support cell migration and new tissue generation. Tissue engineering scaffolds allow for cell seeding and have the ability to release drugs [12,13].

This study uses a scaffold made from the polymer polycaprolactone (PCL), which is a well-known biomaterial and is hydrolytically degraded over a period of one or two years. It is used in several commercially available medical products.

This study investigated the ability to close an ex vivo herniation made in a porcine IVD with a scaffold and soft anchors and the impact on the motion segment movements.

Materials and methods

Test specimens

Nine porcine lumbar spine motion segments were used for testing the repair method. These specimens were cut out of spines harvested from three 40 kg pigs obtained from an abattoir. L1–L6 was cut into motion segments and soft tissue and muscles were removed leaving the posterior elements, pedicles, lamina, and facets intact. Motion segments' ends were embedded with low melting point bismuth alloy to mount in the testing machine. The annulus defect was made with a 3 mm biopsy punch (Miltex, Japan), excising a full thickness annulus biopsy. This left a 3 mm hole with the NP visibly bulging out when manipulated. NP was left in the disc.

Closure

A porous PCL scaffold was used as a plug for the circular defect (Figure 1). To close the defect, scaffolds were press fitted all the way into the defect, hence reaching 8 mm into AF and disc space. Next they were secured with soft anchors (Juggerknot 1.4 mm, Biomet) inserted in the vertebral body and sutured through the AF and scaffold (Figure 2). NP was left untouched in the disc space. The scaffold was made by 3D printing mats 200 µm fibers in layers consecutively angled 60 degrees on top of each to emulate the fiber direction of the AF. From these mats, individual scaffolds were cut out into cylinders 4 mm in diameter and 8 mm long using a biopsy punch.

To increase surface area, scaffolds were modified by partially dissolving the surfaces of the scaffold through immersion in 100% dioxane for 10 s followed by immersion in 80% ethanol/water to resolidify the polymer in a microporous arrangement. Finally, the scaffolds were treated with 5 M NaOH for 1 h to increase surface hydrophilicity by basic hydrolysis of the superficial polymer chains.

thumbnail Figure 1

The scaffold, A: close up of the scaffold used for annulus fibrosus closure. B: SEM image of scaffold showing fiber surface and the porous design. Cell migration and survival and thus new tissue formation, is dependent on the scaffolds design features. These scaffolds were made on a 3D printer that allows control of fiber thickness, fiber pattern and pore size.

thumbnail Figure 2

Each motion segment had the same test three times. A: in healthy native condition, B: with a 3 mm defect in the annulus fibrosus, C: after closing the defect with scaffold and soft anchors. Both ends are embedded in bismuth to insure rigid fixation.

Biomechanical testing

Each motion segment was tested three times − first time in native condition, second time with the defect simulating a herniation made in the antero-lateral part of the AF, and the third time with the defect repaired as described above. Biomechanical testing was done by placing the specimens in a custom made jig which allowed flexion/extension, bi-lateral bending and rotation (Figure 3). A maximum moment of 2 Nm was applied with a rate of 1 degree/s. To minimize the effect of hysteresis the motion segments went through ten loading cycles before data were obtained. Specimens were kept moist by covering with a saline soaked cloth. Finally, a push out test was performed applying axial compression until plug failure or 4000 N. For applying load and measuring displacement a servo hydraulic testing machine (Instron, Norwood, MA, USA) was used, acquiring data for all three directions and push out. Range of motion (ROM), neutral zone (NZ) and neutral zone stiffness (NZS) were obtained from load deflection data (Figure 4). NZ defined as region with minimal stiffness was measured as the angulation deference between flexion and extension at zero load. NZS was the slope at zero load.

The assumption of normality was checked by Q-Q plots, (Stata 12, Statacorp, USA). Groups were compared by means and Students t-test as a paired design. All p-values less than 0.05 were considered significant.

thumbnail Figure 3

Test specimens were placed in a jig, seen on picture, that moves in 3 ways, flexion–extension, lateral bending and rotation. Load was applied by a servo hydraulic machine, which recorded load and displacement. By plotting load-displacement data, a sigmoid curve is drawn from where range of motion, neutral zone and neutral zone stiffness can be calculated.

thumbnail Figure 4

When load deflection data was plotted, two sigmoid curves were obtained, representing flextion and extension movement. Range of movement was measured as the maximum loading in each direction. Difference in intersection with the zero bar of load indicates the neutral zone. Neutral zone stiffness is the slope at zero load.

Results

All plugs remained in the AF during the final push out test. A total axial pressure of 4000 N was applied in the axial direction with no failure. But, in all specimens NP leaking through the pores of the scaffold was observed. This happened at pressures ranging from 300 to 3100 N.

Flexion/extension tests all showed increased ROM, NZ and NZS when applying the defect. Repairing the defect decreased the parameters again (Figure 5). This change was significant for ROM (p < 0.0003) and NZS (p < 0.004). The change in NZ was not significant (p < 0.09), though following the same pattern (Table 1).

Lateral bending showed the same pattern as flexion–extension, but only changes in ROM were found to be significant (p < 0.005) (Table 2).

Rotation showed a significant increase in ROM from 1.65(1.35; 1.96) to 1.81(1.41; 2.22), (p < 0.01) and was reduced again to 1.67(1.31; 2.02) (p < 0.02) when repaired (Table 3).

thumbnail Figure 5

Graphs showing results of the 3 movements, flexion–extension, lateral bending and rotation. Means shown with standard deviations. Range of motion was increased when inducing a defect in AF and decreased when closing the defect, p < 0.0003. Neutral zone was also increased when applying the defect and decreased when closing it, but not significantly. Neutral zone stiffness also an indicator of stability in the motion segment showed deterioration when the AF was injured, but regained when the injury was closed.

Table 1

Mean values with confidence intervals − Flexion–extension.

Table 2

Mean values with confidence intervals − Lateral bending.

Table 3

Mean values with confidence intervals − Rotation.

Discussion

This study shows that a defect in the AF change the biomechanical properties of the motion segment, by increased ROM, NZ and NZS. It seems logical that when an IVD whose function relies on it to maintain pressure gets punctured, it loses stability. The impaired function of AF is likely to affect stability as well [6,14]. Closing the defect with a material with higher stiffness than the surrounding tissue, could possibly add to the rigidity in the motion segment. But, in this study, stability is regained when the defect is closed, and there is no significant difference between the healthy and the repaired motion segment. AF tissue has an elastic modulus around 0.42–0.82 MPa [15], but this scaffold has an elastic modulus about 6.8 MPa, which indicates more rigidity than the native AF. Although it did not to affect the motion segment stability, it might affect the discs ability to resist leaking. The purpose of using a scaffold is to promote tissue generation that resembles the native tissue. Fibrotic tissue, which has lower strength and elasticity, might occur anyway in some amount. This and integration of the more rigid scaffold in the AF will conceivably impair the resistance to the intradiscal pressure and a new herniation.

With exception of compression, no leakage was observed during lateral bending, flexion–extension or rotational testing, presumably due to the scaffold restoring some of the integrity of AF and thus helping to keep the pressure in the NP.

This ex vivo AF defect does not resemble a clinical herniation. The experimental set-up was designed to investigate the mechanical impact made by a defect in AF and how the repair worked. AF defects in clinical herniations can be very heterogeneous and the biomechanical properties of the IVD very different from those seen in a lab. This is one limitation that needs to be considered in this study and needs to be remembered when evaluating the AF repair method. Despite of this, previous studies have shown that the porcine spine is a very good approximation of the human spine, when it comes to anatomy and biomechanical properties [15,16]. The axial load on the IVD is most likely comparable [15]. Experiments have shown that the intradiscal pressure in humans can reach 2.3 MPa by lifting a 20 kg object with bent back [17]. In an experiment conducted by Bron et al. [18], an axial pressure of 600 N gave an intradiscal pressure of 3 MPa, in a similar set-up. In this experiment, the scaffold remained in the AF defect at loads up to 4000 N, but NP began to leak out at much lower loads.

Over the past few years, various methods for repairing AF have been examined experimentally both ex vivo and in vivo [1821]. This is to our knowledge the first study to combine a plug and soft anchors in repairing the AF. Suturing and glue have been tested, but both the processes do not seem to have enough strength to withstand the mechanical load [22,23]. When closing a defect with only suture, tension is built up in the defect area as the suture is tightened. If the pressure inside a ring increases, it will increase the tension in the wall and the defect. This could result in failure of the repair. By doing the opposite, expanding the defect with a plug, presumably less tension will build up. This might prevent failure in closing the defect and also relieve pressure from other places in the annulus with poor condition. A caveat is that the plug will be expelled by the internal pressure in the disc if not secured in some way. Bron et al. examined polyethylene plugs with barbs in an in vivo study with goats. These were able to resist a compression force of 1000 N, but when used in vivo did damage to the endplates [18].

Mechanical tests of this scaffold showed an elastic modulus about 6.8 MPa, compared to hyaline cartilage of 0.5–0.9 MPa [24]. These values indicate a slightly harder plug than the native AF, but not likely to damage the endplates.

Since 3D printed scaffolds can be made with nearly complete design freedom, our approach shows great optimization opportunities. In future investigations, we will study the use of a differentiated pore sizes to keep NP inside while maintaining a compliance that matches that of the AF. NP replacement together with AF repair has to be tested as well.

This project was undertaken to design a scaffold for AF repair and evaluate its biomechanical function. The effect on spinal motion segment was increased stability. It did not manage to contain the NP in compression test, but did stay in the defect. Further research should focus on optimizing the scaffold and in vivo testing for evaluating biomechanical function and investigating biointegration.

Conflicts of interest

The authors declare that they have no conflicts of interest in relation to this article.

Acknowledgements

The authors have received financial support for this study from: (1) Lundbeck Foundation Center for Nanomedicine and (2) Danish Council for Strategic Research: “Individualized Musculoskeletal Regeneration and Reconstruction Network”.

References

  1. Deyo RA, Weinstein JN (2001) Low back pain. New Engl J Med 344, 363–370. [CrossRef] [PubMed] [Google Scholar]
  2. Atlas SJ, Keller RB, Wu YA, Deyo RA, Singer DE (2005) Long-term outcomes of surgical and nonsurgical management of sciatica secondary to a lumbar disc herniation: 10 year results from the Maine lumbar spine study. Spine 30, 927–935. [CrossRef] [PubMed] [Google Scholar]
  3. Weinstein JN, Lurie JD, Tosteson TD, Tosteson AN, Blood E, Abdu W, Herkowitz H, Hilibrand A, Albert T, Fischgrund J (2008) Surgical versus nonoperative treatment for lumbar disc herniation: four-year results for the Spine Patient Outcomes Research Trial (SPORT). Spine 33, 2789–2800. [CrossRef] [PubMed] [Google Scholar]
  4. Iguchi T, Kanemura A, Kasahara K, Sato K, Kurihara A, Yoshiya S, Nishida K, Miyamoto H, Doita M (2004) Lumbar instability and clinical symptoms: which is the more critical factor for symptoms: sagittal translation or segment angulation? J Spinal Disord Tech 17, 284–290. [CrossRef] [PubMed] [Google Scholar]
  5. Haughton VM, Rogers B, Meyerand ME, Resnick DK (2002) Measuring the axial rotation of lumbar vertebrae in vivo with MR imaging. AJNR Am J Neuroradiol 23, 1110–1116. [PubMed] [Google Scholar]
  6. Fujiwara A, Lim TH, An HS, Tanaka N, Jeon CH, Andersson GB, Haughton VM (2000) The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine. Spine (Phila Pa 1976) 25, 3036–3044. [CrossRef] [PubMed] [Google Scholar]
  7. Sakai D, Mochida J, Yamamoto Y, Nomura T, Okuma M, Nishimura K, Nakai T, Ando K, Hotta T (2003) Transplantation of mesenchymal stem cells embedded in Atelocollagen® gel to the IVD: a potential therapeutic model for disc degeneration. Biomaterials 24, 3531–3541. [CrossRef] [PubMed] [Google Scholar]
  8. Chou AI, Nicoll SB (2009) Characterization of photocrosslinked alginate hydrogels for nucleus pulposus cell encapsulation. J Biomed Mater Res Part A 91, 187–194. [CrossRef] [Google Scholar]
  9. Bendtsen M, Bunger CE, Zou X, Foldager C, Joregensen HS (2010) Autologous stem cell therapy maintains vertebral blood flow and contrast diffusion through the endplate in experimental IDD. Spine (Phila Pa 1976) 36(6), E373–E3739. [CrossRef] [Google Scholar]
  10. Guterl CC, See EY, Blanquer SB, Pandit A, Ferguson SJ, Benneker LM, Grijpma DW, Sakai D, Eglin D, Alini M, Iatridis JC, Grad S (2013) Challenges and strategies in the repair of ruptured annulus fibrosus. Eur Cell Mater 25, 1–21. [CrossRef] [PubMed] [Google Scholar]
  11. Bron JL, Helder MN, Meisel HJ, Van Royen BJ, Smit TH (2009) Repair, regenerative and supportive therapies of the annulus fibrosus: achievements and challenges. Eur. Spine J. 18, 301–313. [CrossRef] [PubMed] [Google Scholar]
  12. Andersen MO, Le DQS, Chen M, Nygaard JV, Kassem M, Bünger C, Kjems J (2013) Spatially controlled delivery of siRNAs to stem cells in implants generated by multi-component additive manufacturing. Adv Funct Mater 23, 5599–5607. [CrossRef] [Google Scholar]
  13. Chen M, Le DQS, Hein S, Li P, Nygaard JV, Kassem M, Kjems J, Besenbacher F, Bünger C (2012) Fabrication and characterization of a rapid prototyped tissue engineering scaffold with embedded multicomponent matrix for controlled drug release. Int J Nanomed 7, 4285–4297. [CrossRef] [Google Scholar]
  14. Schmidt TA, An HS, Lim TH, Nowicki BH, Haughton VM (1998) The stiffness of lumbar spinal motion segments with a high-intensity zone in the anulus fibrosus. Spine (Phila Pa 1976) 23, 2167–2173. [CrossRef] [PubMed] [Google Scholar]
  15. Smit TH (2002) The use of a quadruped as an in vivo model for the study of the spine − biomechanical considerations. Eur Spine J 11, 137–144. [CrossRef] [PubMed] [Google Scholar]
  16. Wilke H-J., Geppert J, Kienle A (2011) Biomechanical in vitro evaluation of the complete porcine spine in comparison with data of the human spine. Eur Spine J 20, 1859–1868. [CrossRef] [PubMed] [Google Scholar]
  17. Wilke HJ, Neef P, Caimi M, Hoogland T, Claes LE (1999) New in vivo measurements of pressures in the intervertebral disc in daily life. Spine 24, 755–762. [CrossRef] [PubMed] [Google Scholar]
  18. Bron JL, van der Veen AJ, Helder MN, van Royen BJ, Smit TH (2010) Biomechanical and in vivo evaluation of experimental closure devices of the annulus fibrosus designed for a goat nucleus replacement model. Eur Spine J 19, 1347–1355. [CrossRef] [PubMed] [Google Scholar]
  19. Hegewald AA, Medved F, Feng D, Tsagogiorgas C, Beierfuss A, Schindler GA, Trunk M, Kaps C, Mern DS, Thome C (2013) Enhancing tissue repair in annulus fibrosus defects of the intervertebral disc: analysis of a bio-integrative annulus implant in an in-vivo ovine model. J Tissue Eng Regen Med 9(4), 405–414. [CrossRef] [PubMed] [Google Scholar]
  20. Chiang CJ, Cheng CK, Sun JS, Liao CJ, Wang YH, Tsuang YH (2011) The effect of a new anular repair after discectomy in intervertebral disc degeneration: an experimental study using a porcine spine model. Spine 36, 761–769. [CrossRef] [PubMed] [Google Scholar]
  21. Bailey A, Araghi A, Blumenthal S, Huffmon GV (2013) Prospective, multicenter, randomized, controlled study of anular repair in lumbar discectomy: two-year follow-up. Spine (Phila Pa 1976) 38, 1161–1169. [CrossRef] [PubMed] [Google Scholar]
  22. Ahlgren BD, Lui W, Herkowitz HN, Panjabi MM, Guiboux JP (2000) Effect of anular repair on the healing strength of the intervertebral disc: a sheep model. Spine 25, 2165–2170. [CrossRef] [PubMed] [Google Scholar]
  23. Heuer F, Ulrich S, Claes L, Wilke HJ (2008) Biomechanical evaluation of conventional anulus fibrosus closure methods required for nucleus replacement. Laboratory investigation. J Neurosurg Spine 9, 307–313. [CrossRef] [PubMed] [Google Scholar]
  24. Athanasiou KA, Rosenwasser MP, Buckwalter JA, Malinin TI, Mow VC (1991) Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage. J Orthop Res 9, 330–340. [CrossRef] [PubMed] [Google Scholar]

Cite this article as: Rickers K, Bendtsen M, Le DQS, Veen AJd, Bünger CE (2018) Biomechanical evaluation of annulus fibrosus repair with scaffold and soft anchors in an ex vivo porcine model. SICOT J, 4, 38.

All Tables

Table 1

Mean values with confidence intervals − Flexion–extension.

Table 2

Mean values with confidence intervals − Lateral bending.

Table 3

Mean values with confidence intervals − Rotation.

All Figures

thumbnail Figure 1

The scaffold, A: close up of the scaffold used for annulus fibrosus closure. B: SEM image of scaffold showing fiber surface and the porous design. Cell migration and survival and thus new tissue formation, is dependent on the scaffolds design features. These scaffolds were made on a 3D printer that allows control of fiber thickness, fiber pattern and pore size.

In the text
thumbnail Figure 2

Each motion segment had the same test three times. A: in healthy native condition, B: with a 3 mm defect in the annulus fibrosus, C: after closing the defect with scaffold and soft anchors. Both ends are embedded in bismuth to insure rigid fixation.

In the text
thumbnail Figure 3

Test specimens were placed in a jig, seen on picture, that moves in 3 ways, flexion–extension, lateral bending and rotation. Load was applied by a servo hydraulic machine, which recorded load and displacement. By plotting load-displacement data, a sigmoid curve is drawn from where range of motion, neutral zone and neutral zone stiffness can be calculated.

In the text
thumbnail Figure 4

When load deflection data was plotted, two sigmoid curves were obtained, representing flextion and extension movement. Range of movement was measured as the maximum loading in each direction. Difference in intersection with the zero bar of load indicates the neutral zone. Neutral zone stiffness is the slope at zero load.

In the text
thumbnail Figure 5

Graphs showing results of the 3 movements, flexion–extension, lateral bending and rotation. Means shown with standard deviations. Range of motion was increased when inducing a defect in AF and decreased when closing the defect, p < 0.0003. Neutral zone was also increased when applying the defect and decreased when closing it, but not significantly. Neutral zone stiffness also an indicator of stability in the motion segment showed deterioration when the AF was injured, but regained when the injury was closed.

In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.